{"product_id":"schneider-electric-homeline-homcrbgk1c-generator-interlock-kit-for-100-125a-qom1-main-outdoor-nema-3r","title":"Schneider Electric Homeline HOMCRBGK1C Generator Interlock Kit for 100–125A QOM1 Main, Outdoor NEMA 3R","description":"\u003cb\u003eSchneider Electric's Square D HOMCRBGK1C interlock kit safely ties a 100–125A Homeline main breaker to a 2‑pole generator backfeed breaker so you can power selected circuits during outages without installing a separate generator panel.\u003c\/b\u003e\n\n\u003cp\u003eThis outdoor-rated interlock kit is designed for Homeline \"S\" Series load centers (NEMA 1 and NEMA 3R) and mechanically prevents the main service breaker and a generator-fed 2‑pole branch breaker from being on at the same time. It allows you to backfeed a generator through a Homeline branch breaker (15–125A) while ensuring service isolation, and it includes labels and wiring guidance to simplify installation and inspection.\u003c\/p\u003e\n\n\u003ch3\u003eHow does this interlock kit maintain safety when using a portable generator?\u003c\/h3\u003e\n\u003cp\u003eThe kit creates a physical lockout between the QOM1 main breaker and the designated 2‑pole generator breaker so both cannot be closed together. That prevents accidental backfeed to utility lines and protects utility workers and equipment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMechanical interlock prevents simultaneous main and generator breaker engagement.\u003c\/li\u003e\n  \u003cli\u003eDesigned for QOM1 2‑pole mains (100–125A)\u003c\/li\u003e\n  \u003cli\u003eWorks with Homeline 2‑pole branch breakers rated 15–125A for generator feed.\u003c\/li\u003e\n  \u003cli\u003eUL listed and ANSI certified for recognized safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWill this kit fit my outdoor Homeline load center?\u003c\/h3\u003e\n\u003cp\u003eYes, the HOMCRBGK1C is made for Homeline \"S\" Series load centers in both NEMA 1 (indoor) and NEMA 3R (outdoor) enclosures, provided the panel uses a QOM1 main breaker. Confirm your load center model and main breaker type before purchase.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCompatible with Homeline \"S\" Series load centers.\u003c\/li\u003e\n  \u003cli\u003eSpecifically interlocks QOM1 2‑pole mains (100–125A).\u003c\/li\u003e\n  \u003cli\u003eIntended for single main breaker panels with space for a 2‑pole branch breaker backfeed.\u003c\/li\u003e\n  \u003cli\u003eIncludes labels and wiring diagram to match installation needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat installation details and accessories are included?\u003c\/h3\u003e\n\u003cp\u003eThe kit ships with the interlock hardware, translation labels, and a wiring diagram so electricians and qualified installers have the documentation needed for correct mounting and inspection. No separate generator subpanel is required, which can save space and cost.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInterlock brackets and hardware matched to Homeline dimensions.\u003c\/li\u003e\n  \u003cli\u003eWiring diagram for correct breaker placement and connections.\u003c\/li\u003e\n  \u003cli\u003eInterlock translation labels for compliance and inspection.\u003c\/li\u003e\n  \u003cli\u003eOutdoor-compatible components for NEMA 3R installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow do I choose the right breaker sizes when using the interlock?\u003c\/h3\u003e\n\u003cp\u003eSelect a Homeline 2‑pole branch breaker sized for the generator output and the circuits you intend to run; the interlock supports branch breakers from 15A up to 125A. Ensure the breaker and wiring match the generator's rated amperage and local electrical codes.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eBranch breaker range supported: 15–125A (2‑pole).\u003c\/li\u003e\n  \u003cli\u003eMatch breaker ampacity to generator continuous and peak ratings.\u003c\/li\u003e\n  \u003cli\u003eVerify conductor sizing and overcurrent protection per code.\u003c\/li\u003e\n  \u003cli\u003eHire a licensed electrician for safe, code-compliant installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho is this for: The HOMCRBGK1C interlock kit is for homeowners and contractors who want a compact, code-friendly way to power selected circuits from a portable or standby generator without adding a separate generator panel. It's ideal for installations using Square D Homeline \"S\" Series load centers with a QOM1 main breaker (100–125A) and for anyone prioritizing mechanical safety, outdoor compatibility, and clear installation documentation.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Can I use this interlock with any Homeline main breaker?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: No — it specifically interlocks QOM1 2‑pole main breakers rated 100–125A. Confirm your main breaker model before buying.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Does this kit require a separate generator panel?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: No — the HOMCRBGK1C lets you backfeed through a Homeline branch breaker without installing a separate generator subpanel.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":56840200126804,"sku":"B0764KM4L4","price":99.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1063\/2652\/4244\/files\/schneider-electric-homcrbgk1c-front-panel-view.jpg?v=1787069490","url":"https:\/\/gardenluxe.co.uk\/products\/schneider-electric-homeline-homcrbgk1c-generator-interlock-kit-for-100-125a-qom1-main-outdoor-nema-3r","provider":"Gardenluxe Uk","version":"1.0","type":"link"}