{"product_id":"heatit-hird-roof-gutter-de-icing-cable-20ft-5w-ft-constant-wattage-etl-csa-certified","title":"HEATIT HIRD Roof \u0026 Gutter De-Icing Cable 20ft — 5W\/ft constant-wattage, ETL\/CSA certified","description":"\u003cp\u003e\u003cstrong\u003eHEATIT HIRD 20FT is a 5W\/ft constant-wattage roof and gutter de-icing cable designed to prevent ice dams and keep gutters and downspouts clear.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eBuilt for cold climates and winter maintenance, this 20-foot heat tape from HEATIT delivers steady, reliable warmth along roof edges, gutters and downspouts. The cable is ETL and CSA certified for full-system safety, and the construction uses XLPE inner insulation with aluminum foil screening and a tinned copper braid for durability. It’s meant to be used on noncombustible roofing materials and fits a range of gutter and roof layouts when installed according to instructions.\u003c\/p\u003e\n\n\u003ch3\u003eHow does this cable stop ice dams and clogged gutters?\u003c\/h3\u003e\n\n\u003cp\u003eThe HIRD cable melts snow and ice where it forms along roof eaves and inside gutters so meltwater can drain rather than refreeze. By maintaining a warmer strip along the critical edges, water flows to downspouts instead of building into ridges that cause ice dams.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eConstant 5W per foot heat output to maintain a consistent melt line\u003c\/li\u003e\n  \u003cli\u003ePlace along roof eaves, inside gutters, and downspouts for continuous drainage\u003c\/li\u003e\n  \u003cli\u003eWorks with common shingle roofs and metal or plastic gutters\u003c\/li\u003e\n  \u003cli\u003ePrevents pooling and reduces risk of freeze-related overflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIs the HEATIT cable safe and easy to test before installation?\u003c\/h3\u003e\n\n\u003cp\u003eYes — the full cable assembly carries ETL and CSA certification for the cable and a UL-certified plug, ensuring thorough component testing. HEATIT includes clear pre-installation testing steps so you can confirm the cable warms correctly before securing it to your roof or gutters.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eFully uncoil the cable so it does not overlap, then plug in briefly\u003c\/li\u003e\n  \u003cli\u003eCable should feel slightly warm within about five minutes during the test\u003c\/li\u003e\n  \u003cli\u003eCertifications cover both cable and plug components for compliance\u003c\/li\u003e\n  \u003cli\u003eTesting helps prevent damage from accidental overlap during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat materials and roof types are compatible with this heat tape?\u003c\/h3\u003e\n\n\u003cp\u003eThe HIRD de-icing cable is designed for noncombustible roofing materials such as asphalt shingles and is suitable for use with metal or plastic gutters and downspouts. It is not intended for combustible roof coverings; always verify local building codes and manufacturer recommendations before installing.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eXLPE inner insulation and 100% aluminum foil screening for electrical protection\u003c\/li\u003e\n  \u003cli\u003eTinned copper braid increases mechanical durability and grounding\u003c\/li\u003e\n  \u003cli\u003eRecommended for asphalt shingles and noncombustible roof assemblies\u003c\/li\u003e\n  \u003cli\u003eCompatible with most standard gutter and downspout materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow do I install and size the cable for my roof and gutters?\u003c\/h3\u003e\n\n\u003cp\u003eSelect a length that covers the eave line, gutter channel, and downspout length you want to protect; HEATIT offers multiple lengths to match common configurations. Install the cable following the included instructions: test uncoiled, secure with approved clips, and avoid crossing or overlapping the cable.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMeasure eave, gutter, and downspout runs before ordering length\u003c\/li\u003e\n  \u003cli\u003eDo not overlap cable; secure it with manufacturer-approved fasteners\u003c\/li\u003e\n  \u003cli\u003ePerform the warm-up test prior to final mounting\u003c\/li\u003e\n  \u003cli\u003eFollow local electrical code for power and grounding requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho this is for: HEATIT HIRD 20FT is aimed at homeowners and property managers in snowy climates who want a dependable, certified solution to reduce ice dams, protect roof edges, and maintain gutter flow through winter. It’s suited to anyone comfortable measuring roof runs and following clear pre-installation testing and mounting instructions, and to installers who require a fully certified, durable heating cable for seasonal roof maintenance.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Can I overlap the HEATIT de-icing cable during installation?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: No. Do not overlap or cross the cable; uncoil fully and test before securing to avoid damage and hotspots.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Is this cable safe for all roof types?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: It’s suitable for noncombustible roofs like asphalt shingles and for metal or plastic gutters. Check local codes for other roof materials.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"HEATIT","offers":[{"title":"Default Title","offer_id":56831134466388,"sku":"B0DCMV48LN","price":58.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1063\/2652\/4244\/files\/heatit-hird-front-packaging_a114f28d-99c9-4460-8ab5-115af07a2399.jpg?v=1787011794","url":"https:\/\/gardenluxe.co.uk\/products\/heatit-hird-roof-gutter-de-icing-cable-20ft-5w-ft-constant-wattage-etl-csa-certified","provider":"Gardenluxe Uk","version":"1.0","type":"link"}